Determination of potassium iodide in table salt

Department of Food Technology and Biochemistry, Faculty of Agriculture, Belgrade-Zemun (1)

Abstract:

The samples of table salt bought in Belgrade supermarkets are analyzed in this paper. The method of indirect iodometry was used in the process of the analysis, and received results were converted into the content of KI in mg/kg of salt. Beside the content of KI, the content of NaCl was also determined, counted to dry meter and water content, and received results were compared with the requests determined by Regulations of Table Salt Quality Meant for Human Diet and by manufacturers' declaration. Received results show that the volumetric method of indirect iodometry, applied in this analysis, is very reliable for determination of potassium iodine in table salt, because of its high precision and reproducibility of the analysis results. All received results show that the samples of table salt which can be bought in supermarkets are according to the demands given by Regulations. Only one sample (evaporated salt) has significantly less mass of KI than it is determined by Regulations, but also by manufacturer's declaration. Measured humidity in the samples of table salt received from sea salt (sample 1) is higher than humidity in the samples received from rock salt as the result of magnesium presence in sea salt, which is hygroscopic material. Although samples 5 and 6 also originate from sea salt, their smaller humidity is the result of additional heating and salt processing.

(544.37 KB)